The TL1 commands are:

2.12.10 Section Trace Provisioning (J0) Rules

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
The TL1 commands are:
Only MXP ports can be used for a timing source. Trunk port is only allowed as a timing reference
if G.709 is off and the termination mode is line or section.
For MXP cards, all client ports are available for timing source irrespective of termination mode.
ENT/ED-OCn
Example of setting port-level synchronization attributes:
ED-OC48::FAC-1-1-1:CTAG:::SYNCMSG=Y,SENDDUS=N:;
ED-OCH
Example of setting port-level synchronization attributes:
ED-OCH::CHAN-6-2:114:::SYNCMSG=N,SENDDUS=Y;:
The client and trunk ports only support the section trace if the payload is
OC-3/OC-12/OC-48/OC-192.
The client and the trunk ports support the section trace only in line/section terminated mode.
In line termination mode the supported trace modes are MANUAL and MANUAL_NO_AIS trace
modes.
In section termination mode the supported trace mode is only MANUAL_NO_AIS trace mode.
The section trace supports 1 or 16 bytes length trace format.
The trace mode of AUTO and AUTO-NO-AIS are not supported.
No trace is applicable for 2R (unframed) payload types, for example, DV-6000, HDTV, and ESCON.
The section trace received string should appear when the card is in transparent-AIS or
TRANSPARENT-SQUELCH termination mode and the payload is OC-3/OC-12/OC-48/OC-192.
When the client port is configured in a Y-cable protection group the received string is always
retrieved from the active client port.
If the line is Y-cable protected trace can only be provisioned on the working port, however the
provisioning will be duplicated between the two ports. Both ports will contain the same values. This
rule applies to the following parameters: Mode, Format, Send String and Expected String.
The MXP_2.5G_10E card is used for client test connection on client ports. For the trunk port the
TTI is used.
The TXP_MR_10E card is used to test connections on client trunk ports.
On MXP_MR_2.5G/MXPP_MR_2.5G cards the trunk port section trace can be provisioned
following the rules for line terminated SONET.
ED-OCn for trace provisioning of client ports provisioned for OCn payload.
Example of provisioning port-level trace:
ED-OC48::FAC-6-1-1:10:::EXPTRC="AAA",TRC="AAA",TRCMODE=MAN,
TRCFORMAT=16-BYTE;
ED-TRC-OCH for trace provisioning of trunk/OCH DWDM ports.
2.12.10 Section Trace Provisioning (J0) Rules