Cisco D9858 Installation And Configuration Manual page 112

Advanced receiver transcoder software
Hide thumbs Also See for D9858:
Table of Contents

Advertisement

Chapter 4 Front Panel Operation
Menu Item
Mode
Delay(sec)
Relay Mode
Cue Trigger Bit
Cue Tone Test
Mode
Run Test
90
Description
Sets the tone sequence mode.
If the Mode was set to */#
(Start/Stop), set the delay, in
seconds, between the start and
stop sequences.
The relay can be programmed
to respond to an alarm or
warning state, or the state of
one of the eight cue trigger
pins. The response is generated
at the Cue Tone/Relay output
on the rear panel of the
receiver.
If the Relay Mode was set to
Trigger, select the cue trigger
bit/pin that will activate the
relay.
Sets the three digit cueing tone
test sequence.
Sets the test sequence mode.
Select and press continue to run
the cue tone test according to
the Cue Tone Test and Mode.
Parameters
* - Start tone only
# - End tone only
*/# - Start and end tones. The end
tone is signaled after waiting the time
specified in Delay(sec).
1 to 255. The default is 30.
Alarm or Trigger
The following table displays the
possible field settings and their
relationship to the receiver output:
Relay
Condition
Mode
Alarm
Unit Power
Off
Alarm State
No Alarm
Trigger Active
(selected in
PNC)
Inactive
1 to 8
000 to 999
* - Start tone
# - End tone
Relay
Contact
NC-
C-No
C
Open Close
Open Close
Close Open
Close Open
Open Close