Window Screen Display And Switching - Mitsubishi Electric Got 1000 Training Manual

Graphic operation terminal
Hide thumbs Also See for Got 1000:
Table of Contents

Advertisement

2.3.5

Window screen display and switching

Screen No. 15
Data 4
Screen No. 15
Screen No. 15
The window screen is displayed by writing the same No. as the window No. of the
screen to be displayed into the switching device used in overlap windows 1, 2.
Two types of writing in the screen switching device are available : writing with the
sequence program, and writing with the GOT touch switch.
Point
When "zero" is written in the screen switching device, the window screen is not
displayed.
Example: When the switching device for base screen is D0, and that for overlap
window 1 is D1.
999
Data 4
999
Data 4
Window Screen
No. 3
Sequence program example
X3
X4
X4
X3
The current values of the switching device are the
below because the GOT displays only base screen
No. 15.
D0 = "15"
D1 = "0"
Turn ON X3 with the sequence program, and D1
value is changed to three.
The GOT displays window screen No. 3 because
D1 value is changed to three.
When closing the window screen, operate either of
the following methods.
• Touch
in the upper right corner of the
window screen.
• Write "zero" as the D1 value in the overlap
window1 screen switching device.
2 - 9
K3
D1
MOV
K0
D1
MOV
Window Screen
No. 3

Hide quick links: