5.3 Numerical input/numerical display settings

5.3.1
Numerical input settings
This function is used to display or write the data stored in the devices of the
controller.
In this section, create a numerical display showing the operating time, and a
numerical input for entering the planned operating time.
Making the settings of numerical input (D10)
(1) Click
on the toolbar (Object), and then click any place on the drawing
screen.
Numerical input:
4 digits for decimal number
Write device: D10
Numerical display:
4 digits for decimal number
Read device: D20
1)
Move the cursor on to the screen, determine
the position for display, and then click the
mouse button.
2)
Click the right mouse button to cancel the
placement mode (+) of the cursor.