Servo Amplifier Life Diagnosis Function; Switching Axis Numbers (Station Numbers) Of Servo Amplifiers - Mitsubishi Electric GOT DRIVE GOT2000 Manual

Graphic operation terminal
Table of Contents

Advertisement

GOT Drive Control (Servo) Interactive Solutions
MR-J5
MR-J4
Key
Feature
26

Servo amplifier life diagnosis function

Supports predictive maintenance functions of servo amplifiers
Challenges
5
Is it possible to check the life of the
servo amplifier with GOT without
connecting it to a PC?
MR-J5
MR-J4
Key
Feature
27

Switching axis numbers (station numbers) of servo amplifiers

Adjust and maintain multiple axes on one screen
Challenges
Creating a screen for each axis of
a servo amplifier is time-consuming
and can result in increased data
storage usage.
Switch to the axis number (station number)
of the servo amplifier you want to monitor
No.
Function
44
Servo amplifier life diagnosis
1
function
Switching axis numbers (station
2
numbers) of servo amplifiers
MR-JET
MR-JE
* Supported by MR-J4-B(-RJ), MR-J4W2-B, MR-J4W3-B, MR-JE-B only. See page 16 for details.
Solutions
Cumulative operation time, on/off counts of inrush relay, and replacement timing of servo
amplifier components (capacitor, relay) can be checked on the GOT. Also, you can notify the
replacement timing of servo amplifier components to on-site workers by using the GOT alarm
function.
Periodic check
MR-JET
MR-JE
* Supported by MR-J4-B(-RJ), MR-J4W2-B, MR-J4W3-B, MR-JE-B only. See page 16 for details.
Solutions
GOT can be used to monitor axes of servo amplifiers by switching the axis numbers so that you
can adjust and maintain multiple axes on one screen. You can reduce the number of screens
and also reduce the time for screen creation and equipment maintenance.
Switching MR-J5-G axis numbers (station numbers) from 1 to 5
Axis No. 1  Axis No. 5
Monitor
Net No. : 1 Station No.: 1
Axis name: Axis name 1
MR-J5-G(-RJ)
MR-J5D1-G4
MR-J5W2-G
MR-J5D2-G4
MR-J5W3-G
MR-J5D3-G4
Motion controller
Axis No.: 1
MR-J5-B(-RJ)
MR-J4-B(-RJ)
MR-J4-
MR-J5W2-B
MR-J4W2-B
A(-RJ)
MR-J5W3-B
MR-J4W3-B
SoftGOT
GT27
GT25
GT21
(Single-ch)*
Sample
End user
Visualization
screen
* The screen image shown
is the connection sample
Life diagnosis screen
screen of MR-J5-G.
Check the smoothing capacitor energization time
or the inrush relay on/off times at a glance
SoftGOT
GT27
GT25
GT21
(Single-ch)*
Sample
End user
OEM
screen
* The screen image shown is the connection
sample screen of MR-J5-G.
Net No. : 1 Station No.: 2
Axis No.: 5
Axis name: Axis name 5
: Supported —: Not supported
MR-J4-
MR-JET-
MR-JE-
MR-JE-
GF(-RJ)
G
B
A
SoftGOT
(Multi-ch)
Predictive
maintenance
SoftGOT
(Multi-ch)
Maintenance
MR-JE-
C

Advertisement

Table of Contents
loading