Table A-1 Malfunction Indicator Lamp Circuit Check - Lamp Does Not Come
"ON" at Ignition Switch ON (But Engine at Stop)
CIRCUIT DESCRIPTION
1. Main fuse
2. Ignition switch
3. Fuse box
NOTE:
For TYPE A and TYPE B, refer to the NOTE in "ECM Terminal Voltage Values Table" for applicable
model.
When the ignition switch is turned ON, ECM causes the main relay to turn ON (close the contact point). Then,
ECM being supplied with the main power, turns ON the malfunction indicator lamp (MIL). When the engine
starts to run and no malfunction is detected in the system, MIL goes OFF but if a malfunction was or is detected,
MIL remains ON even when the engine is running.
INSPECTION
Step
1
MIL Power Supply Check
1) Turn ignition switch ON.
Do other indicator / warning lights in combina-
tion meter comes ON?
4. Main relay
5. Malfunction indicator lamp in
combination meter
6. "FI" fuse
Action
ENGINE GENERAL INFORMATION AND DIAGNOSIS 6-43
7. "IG" fuse
8. "IG COIL METER" fuse
Yes
Go to Step 2.
[A] : Case of TYPE A is shown
(See NOTE)
[B] : Case of TYPE B is shown
(See NOTE)
No
"IG" fuse blown, main fuse
blown, ignition switch mal-
function, "B/W" circuit
between "IG" fuse and
combination meter or
poor coupler connection
at combination meter.