Fujitsu Eternus web GUI User Manual page 519

For eternus dx90 s2; eternus dx80 s2; eternus dx410 s2; eternus dx440 s2
Table of Contents

Advertisement

Chapter 11 System Management
11.2 Functions in the Action Area for System
2
3
Click the [Immediately Send Log Manually] tab to change the screen.
Specify the parameters, and click the [Execute] button.
Incident Number
Input the incident number to be added to the log to be sent.
The following input conditions apply:
-
Up to 15 characters
-
Alphanumeric characters and symbols (except spaces)
Expander Log Collection
Specify whether to collect the Expander log. To obtain the Expander log, select the
"Collect" checkbox.
Time Range Specified
Select whether to specify the time range to export logs.
To specify the time to send log, select the "Specify" checkbox, and specify the start and
end time.
If the time range has been specified, some of the logs just before and after the
specified time range may also be collected.
Start Time
When "Specify" has been selected for "Time Range Specified", specify the start time for
collecting logs.
-
YYYY-MM-DD hh:mm:ss (YYYY: Year (AD), MM: Month (01 - 12), DD: Day (01 -
31), hh: Hour (00 - 23), mm: Minute (00 - 59), ss: Second (00 - 59))
End Time
When "Specify" has been selected for "Time Range Specified", specify the end time for
collecting logs.
-
YYYY-MM-DD hh:mm:ss (YYYY: Year (AD), MM: Month (01 - 12), DD: Day (01 -
31), hh: Hour (00 - 23), mm: Minute (00 - 59), ss: Second (00 - 59))