Fujitsu Eternus web GUI User Manual page 372

For eternus dx90 s2; eternus dx80 s2; eternus dx410 s2; eternus dx440 s2
Table of Contents

Advertisement

Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
VLAN ID
Enter the VLAN ID for the target port between 0 and 4095.
Make sure to set the same value for the VLAN ID as the VLAN ID of the FCoE switch
that is to be connected to.
Set Fabric Name
Specify "Auto" to enable the automatic setting for the fabric name of the target port.
Specify "Fixed" to enable the fixed setting.
When "Auto" is specified, the fabric name of the connected FCoE switch is
automatically obtained and does not need to be specified.
When "Fixed" is specified, enter the fabric name.
"Auto" should be set for normal operation. When "Fixed" is specified, connection to any
switch other than the specified FCoE switch cannot be performed.
Fabric Name
Enter the fabric name (WWN of FCoE) of the target port.
Frame Size
Select the frame size of the target port.
"Frame Size" specifies the length of the communication information.
-
2048 bytes
-
1024 bytes
-
512 bytes
Reset Scope
Specify the reset scope of the target port.
Reset scope is the range where the command reset request from the server is
performed, when the target port is connected to multiple servers.
-
I_T_L (I: Initiator, T: Target, L: LUN)
Reset (cancel) the command request from the server that sent the command reset
request.
-
T_L (T: Target, L: LUN)
Reset (cancels) the command request from all of the servers that are connected to
the port.
Release Reservation if Chip is Reset
Select whether to "Enable" or "Disable" the function to release the reserved status of
the volume when the target port (chip) is reset.
ETERNUS Web GUI User's Guide
Copyright 2011 FUJITSU LIMITED
372