ABB IRC5 Product Manual page 91

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

Connection of safety chains
The diagram below shows the dual channel safety chain.
The supply from internal 24V and 0 V is displayed. For external supply of GS and
AS check the circuit diagram.
xx0100000166
Technical data per chain
Limit switch
External connectors
GS/AS/SS load at 24 V
GS/AS/SS closed "1"
GS/AS/SS open "0"
External supply of GS/AS/SS
GS/AS/SS Filter time
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
2.5.12 Connection of the MOTORS ON/MOTORS OFF circuit
Load: 300 mV
Max. voltage drop: 1 V
Load: 10 mA
Max. voltage drop: 4 V
25 mA
>18 V
< 5 V
Max. + 35 VDC
Min. - 35 VDC
2.0 ms
© Copyright 2007-2024 ABB. All rights reserved.
2 Installation and commissioning
Terminal
X5, X6
X22, X24
i
Continues on next page
Continued
Location
Control Module
Drive Module
91