2 Installation and commissioning
2.5.3 Connecting power supply to PMC small
Continued
Connecting incoming power to the Drive Module
Use this procedure to connect power supply to the drive module.
1
2
3
4
5
68
Action
Place the line filter and transformer
near to the drive module and they
must be on the same ground.
Connect the incoming power to the
Line filter (LINE).
Route, strap and connect the three
phase wires to XT16:1, 2 and 3.
Route, strap and connect the two
phase wires to XT16:4 and 5.
Route, strap and connect the earth
cable to PE.
© Copyright 2007-2024 ABB. All rights reserved.
Note/illustration
xx0600003315
D
C
B
A
xx0600003316
A: incoming power 3x262V 10A wires
B: incoming 230V wires
C: incoming earth cable
D: outgoing 230V to the Control Module
CAUTION
Separate the power supply 2-phase wires from
the 3-phase wires. These are disturbing on the
Line filter LOAD side.