Replacement Of Safemove Board Dsqc 647 - ABB IRC5 Product Manual

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

4 Repair

4.15 Replacement of SafeMove board DSQC 647

4.15 Replacement of SafeMove board DSQC 647
General
A SafeMove safety controller, SafeMove board, is mounted if the option SafeMove
is used.
Location
The SafeMove board is mounted behind the axis computer.
PMC small:
B
A
xx1000000980
A
B
Continues on next page
204
Note
After replacement of the safety controller, the SafeMove configuration must be
downloaded to the new safety controller and then validated. For more information,
see Application manual - SafeMove1.
SafeMove board
Axis computer
© Copyright 2007-2024 ABB. All rights reserved.
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB

Advertisement