Connections The module must be assembled in the first vacant slot of the terminal box after Ekip Supply , either on the
Power supply Ekip Com Synchrocheck is supplied directly by the Ekip Supply module to which it is connected.
Output Ekip Synchrocheck has an output (K S1 - K S2) used as synchronism contact.
248 | © 2023 ABB | 1SDH001330R1002 - ECN000297030
circuit-breaker (fixed version) or on the fixed part (withdrawable version).
For references about the connection and terminals, please consult document 1SDM000091r0001; use
AWG 22-16 cables with 1.4 mm maximum outer diameter for the external cabling.
To connect the module to Ekip Touch, please consult document 1SDH001000r0513.
NOTE: communication between Ekip Touch and the module is interrupted in the absence
of auxiliary power supply
Input Ekip Synchrocheck has an input (V S1 - V S2) for reading voltage, operation of which is ensured within the
ranges and with the performance given below:
Component
Operating range
Voltage
0÷120 VAC
Frequency
30÷80 Hz
(3)
Phase
(5)
-
(1)
the accuracy values refer to normal operating ranges, as established by IEC 61557-12
with busbar activated
(2)
with the busbar activated, frequency measurement starts at ≥ 36 V AC and ends at ≤ 32 V AC
(3)
measured voltage
in the absence of harmonic distortion
(4)
phase measurement refers to the phase difference between internal and external voltage
(5)
Isolation transformer
An isolating transformer with the characteristics given below must always be installed between the
external contacts of the circuit-breaker and the input of the module:
Characteristics
Mechanical
Electrical
The output is insulated from the unit and input, and has the following electrical characteristics:
Characteristics
Maximum switchable voltage
Breaking capacity
Dielectric strength between open contacts
Dielectric strength between each contact and
coil
data relating to a resistive load
(1)
Normal operating range
10 ÷ 120 VAC
30 ÷ 80 Hz
-180 ÷ +180 °
Description
• fixing: EN 50022 DIN 43880 rail
• material: self-extinguishing thermoplastic
• protection class: IP30
• electrostatic protection: with earth connector shield
• accuracy class: ≤ 0,2
• performance: ≥ 4 VA
• overload: 20% permanent
• insulations: 4 kV between inputs and outputs, 4 kV between screen and
outputs, 4 kV between screen and inputs
• frequency: 45 to 66 Hz
Maximum limit
(1)
150 VDC / 250 VAC.
2 A @ 30 VDC, 0,8 A @ 50 VDC, 0,2 A @ 150 VDC,
4 A @ 250 VAC
1000 VAC (1 minutE @ 50 Hz)
1000 VAC (1 minutE @ 50 Hz)
External electronic accessories
12 - Ekip Synchrocheck
ABB | SACE Emax 2
Accuracy
(1)
1 %
(2)
0,1 %
(4)
1 °