Protection degree SACE Emax 2 circuit-breakers guarantee the following protection degrees:
Dissipated power To guarantee the performance of the switchgear in terms of uninterrupted rated capacity, the design of
174 | © 2023 ABB | 1SDH001330R1002 - ECN000297030
• IP20 for circuit-breakers in fixed or withdrawable versions, excluding the terminals
• IP30 for the front parts of the circuit-breaker when it is installed in a switchboard with IP30 flange
mounted on the door
• IP54 in circuit-breakers equipped with an optional IP54 transparent flange fitted to the front door
of the switchboard
the switchgear must take into account the power dissipated by switchgear and controlgear and by the
installed live parts. Dissipated powers are calculated according to the standard IEC 60947. The values
indicated in the table refer to the total power for each three-phase circuit-breaker with balanced loads
with a current flow equal to the rated uninterrupted current Iu. These power dissipations are measured
according to the standard IEC 60947. The values indicated in the table refer to the total power of the
circuit-breakers in three-pole and four-pole versions with balanced loads and a current flow equal to the
rated uninterrupted current Iu at 50/60 Hz.
Dissipated power [W]
E1.2 B/C/N
Iu
F
W
(1)
(2)
630A
31
62
800A
50
100
1000A
78
156
1250A
122
244
1600A
201
400
2000A
2500A
3200A
4000A
5000A
6300A
Dissipated power [W]
E1.2
E2.2
Iu
B/N/S - A
B/N/S - A
F
W
F
(1)
(2)
(1)
250A
7
14
400A
17
35
15
800A
59
118
48
1200A
125
250
100
1600A
170
2000A
2500A
3200A
3600A
4000A
5000A
6000A
Fisso - Fixed - Fest - Fixe - Fijo
(1)
Estraibile - Withdrawable - Ausfahrbarer - Débrochable - Extraíble
(2)
E2.2 B/N/S/H
E4.2 N/S/H/V
F
W
F
(1)
(2)
(1)
34
72
53
113
83
176
136
288
212
450
267
550
425
465
E2.2 H/V
- A
E4.2
E2.2 2000A
S/H/V - A
B/N/S - A
W
F
W
F
W
(2)
(1)
(2)
(1)
22
15
22
73
48
68
44
58
152
99
138
86
114
260
167
233
143
189
250 350
211
279
310
410
ABB | SACE Emax 2
E6.2 H/V/X
W
F
(2)
(1)
743
900
309
483
767
E4.2 L - A
E6.2
E4.2 3200A
H/V - A
S/H/V - A
F
W
F
W
(2)
(1)
(2)
(1)
(2)
42
49
81
111
132
181
193
264
280 384
445 610
323
438
578
395 536
476
646
700 950
1484
Mechanical characteristics
4 - Technical characteristics
W
(2)
544
850
1350
E6.2 L - A
F
W
(1)
(2)
476
646
700 950