9.3.5 TPC Output Triggering by Input Capture

TPC output can be triggered by ITU input capture as well as by compare match. If GRA functions
as an input capture register in the ITU channel selected in TPCR, TPC output will be triggered by
the input capture signal. Figure 9-8 shows the timing.
ø
TIOC pin
Input capture
signal
NDR
DR
Figure 9-8 TPC Output Triggering by Input Capture (Example)