Electrical Installation; Start-Up; Configuration Parameters - ABB ACS560 Hardware Manual

0.75 to 160 kw, 1.0 to 215 hp
Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

Electrical installation

Use 0.5 ... 2.5 mm
If you connect an inductive load (relay or contactor coil, motor) protect the relay
contacts with a varistor, RC filter (AC) or diode (DC). Install the protective
component as close to the inductive load as possible. Do not install protective
components at the relay output terminals.
Identification
X103
4
1
COM
Common
2
NC
Normally closed
3
NO
Normally open
X104
5
1
COM
Common
2
NC
Normally closed
3
NO
Normally open
X105
6
1
COM
Common
2
NC
Normally closed
3
NO
Normally open
X106
7
1
COM
Common
2
NC
Normally closed
3
NO
Normally open

Start-up

To configure the operation of the relays added with the BREL-01 module:
1.
Power up the drive.
2. Set the parameter 15.01 Extension module type to 5 (BREL).
3. Use the control panel on the drive and set the parameters for relay outputs
RO4...RO7 in 15 I/O extension module . Refer to the for parameter descriptions.

Configuration parameters

The configuration parameters of the BREL-01 module are in group 15 I/O extension
module .
No.
Name/Value
15 I/O extension module
Optional panel bus adapters and extension modules 229
2
(20 ... 14 AWG) cable with a sufficient voltage rating.
Relay outputs RO4...RO7:
Max. switching voltage: 250 V AC / 30 V DC
Max. switching current: 2 A
Galvanically isolated.
Description
Description
Def /
FbEq16/32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents