30 Operation principle and hardware description

Operation principle

The ACS560 is a drive for controlling asynchronous AC induction motors.
The figure below shows the simplified main circuit diagram of the drive.
ACS560
L1
L2
L3
1
L1
L2
L3
1
Rectifier. Converts alternating current and voltage to direct current and voltage.
2
DC link. DC circuit between rectifier and inverter.
3
Inverter. Converts direct current and voltage to alternating current and voltage.
1
2
4
R- UDC+ R+ UDC-
2
3
5
3
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W