Terminal And Lead-Through Data For The Power Cables - ABB ACS560 Hardware Manual

0.75 to 160 kw, 1.0 to 215 hp
Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

150 Technical data
Drive
type
Main cir-
ACS560-
cuit nom-
inal I 1N ,
I N
W
3 phases U N = 400V (380...480V)
02A6-4
35
03A3-4
42
04A0-4
50
05A6-4
68
07A2-4
88
09A4-4
115
12A6-4
158
017A-4
208
025A-4
322
033A-4
405
039A-4
500
046A-4
594
062A-4
810
073A-4
999
088A-4
1215
106A-4
1485
145A-4
1440
169A-4
1940
206A-4
2310
246A-4
3300
293A-4
3900
1) The table shows the typical drive losses when it operates at 90% of the nominal output frequency and
100% of the nominal output current. See also

Terminal and lead-through data for the power cables

Input, motor, resistor and DC cable lead-throughs, maximum wire sizes (per phase)
and terminal screw sizes and tightening torques ( T ) are given below.
1)
Thermal losses
Control
Control
circuit
circuit
Min. load
Max. load
W
W
0.3
9
0.3
9
0.3
9
0.3
9
0.3
9
0.3
9
0.3
9
0.3
9
0.3
9
3.5
25
3.5
25
3.5
25
3.5
25
3.5
25
3.5
25
3.5
25
4.1
36
4.1
36
4.1
36
4.1
36
4.1
36
Air flow
Main circuit
and control
circuit Max.
load
m 3 /h
W
44
51
59
77
97
124
167
63
217
128
331
128
430
116
525
116
619
116
835
280
1024
280
1240
280
1510
435
1476
435
1976
450
2346
550
3336
550
3936
1150
Energy efficiency data (ecodesign) (page
Noise
dB(A)
57
63.10
57
63.10
57
63.10
57
63.10
57
63.10
57
63.10
58.80
65.80
65.80
70
70
70
62
62
62
67
67
67
67
65
65
159).
Frame
size
R0
R0
R0
R0
R0
R0
R1
R2
R2
R3
R3
R3
R4
R4
R5
R5
R6
R7
R7
R8
R8

Hide quick links:

Advertisement

Table of Contents
loading