Event
Overview
code
00C65
Time synchronization receive processing failure
00C70
CANopen initialization failure
00C71
Initialization failure (parameter mismatch between
master and slave stations)
00C72
Maximum response time mismatch during time-
managed polling
00C80
Slave station that does not support CC-Link IE TSN
Protocol version 2.0 detected
00C81
CC-Link IE TSN Class settings mismatch
Security
Event
Overview
code
10200
Remote password lock
10201
Remote password unlock successful
10202
Remote password unlock failed
10300
Access from IP restricted with IP filter setting
Operation
Event
Overview
code
24100
Own station: Parameter change/new parameter
reception
24300
Own station: Enabling remote device test function
24301
Own station: Failure in enabling remote device test
function (Programmable controller CPU is not in STOP
state (excluding a stop error))
24302
Own station: Failure in enabling remote device test
function (Own station is not set as a master station.)
24303
Own station: Disabling remote device test function
(SB0016 is turned off.)
24304
Own station: Disabling remote device test function
(Programmable controller CPU is in RUN or PAUSE
state).
24305
Own station: Disabling remote device test function
(Programmable controller CPU indicates a stop error.)
24307
Network number, station number, IP address setting/
change execution
24F00
Another station: CPU operating status change
detection
Cause
The receive processing for time synchronization failed.
A communication error occurs in CANopen initialization processing.
During initialization processing at the start of control communication, a parameter
mismatch was detected between the master station and slave stations.
A mismatch was detected in the maximum response time during time-managed polling.
Update the version of the engineering tool and the slave stations to the latest version,
and then retry the operation.
A slave station that does not support CC-Link IE TSN Protocol version 2.0 was detected.
A mismatch was detected between the parameter of the master station and the CC-Link
IE TSN Class of the slave stations.
Cause
The lock processing of the remote password was performed.
The unlock processing of the remote password was succeeded.
The unlock processing of the remote password has failed.
Accessed from IP address restricted with the IP filter setting.
Cause
Parameter was changed. Or new parameter was received at power-on.
Remote device test function was enabled.
The operating status of the programmable controller CPU is not in STOP state
(excluding a stop error), and enabling remote device test function failed.
The own station is not set as a master station and enabling remote device test function
failed.
Remote device test function was disabled because SB0016 (Remote device forced
output request) has been turned off.
Remote device test function was disabled because operating status of the
programmable controller CPU has been changed to RUN or PAUSE state.
Remote device test function was disabled because a stop error has occurred in the
programmable controller CPU.
Setting or change of the network number, station number, or IP address of the own
station was executed.
Operating status of the CPU module on another station was changed.
4 TROUBLESHOOTING
237
4.7 Event List
4