1.7

Safety Communications

This section describes the safety communication function.
The following modules are required to use the safety communications.
• Safety CPU and safety function module with a firmware version of "20" or later
• The RJ71GN11-T2 with a firmware version of "10" or later
Communications with safety stations
This function establishes a safety connection and performs one-on-one safety communications periodically between safety
stations in the same network.
Safety data is exchanged by using the safety device of the Safety CPU set by "Safety Communication Setting" under "Basic
Settings" from a program.
Whether a safety connection is established or not can be checked in 'Safety refresh communication status of each safety
connection (1st module)' (SA\SD1008 to SA\SD1015) of the Safety CPU.
*1 Safety special register areas for the first RJ71GN11-T2. For safety special register areas for the second or later RJ71GN11-T2, refer to
the following.
 MELSEC iQ-R CPU Module User's Manual (Application)
Stations supporting safety communications
Safety communications can be performed between the following stations (safety stations).
• Master station (safety station) (1)  local station (safety station) (2) (4)
• Master station (safety station) (1)  remote station (safety station) (3)
(1)
(2)
Standard station (5) (6) can be mixed in one network for system configuration. However, safety
communications (7) cannot be performed with standard stations (5) (6). Only standard communications (8)
can be performed.
1 FUNCTIONS
86
1.7 Safety Communications
(3)
(4)
(7)
(7)
*1
(5)
(8)
(8)
(6)