Error
Error definition and causes
code
D25FH
A remote instruction was executed from the
module with a station type which cannot
execute it.
D260H
A remote instruction was executed from the
module with a station type which cannot
execute it.
D262H
The total number of slave stations specified
in the CCPASET instruction is incorrect.
D263H
The constant link scan time setting of the
CCPASET instruction is incorrect.
D264H
The station number setting of the CCPASET
instruction is incorrect.
D265H
The station number specified for the
CCPASET instruction is already in use.
D266H
The number of occupied stations specified in
the CCPASET instruction is incorrect.
D267H
The station type of the CCPASET instruction
is incorrect.
D268H
The link device range assignment specified
for each station in the CCPASET instruction
is incorrect.
D269H
The station type of the REMFR/REMTO/
REMFRD/REMTOD/REMFRIP/REMFRDIP/
REMTOIP/REMTODIP instruction target
station is not a remote station.
D26AH
The target station of the REMFR/REMTO/
REMFRD/REMTOD/REMFRIP/REMFRDIP/
REMTOIP/REMTODIP instruction does not
exist.
D26BH
The network number setting of the
CCPASET instruction executing station is
incorrect.
D26CH
The station type and station number of the
CCPASET instruction executing station are
incorrect.
D273H
The request data size of transient
transmission is incorrect.
D275H
Other dedicated instructions are in
execution, and the executed instruction
cannot be processed.
D27AH
The own station number set in the UINI
instruction is incorrect.
Action
Stations other than the master station cannot execute a remote instruction.
Modify the program so that remote instructions are not executed from
stations that cannot use them.
Stations other than the master station cannot execute a remote instruction.
Modify the program so that remote instructions are not executed from
stations that cannot use them.
• Execute the instruction again after correcting the total number of slave
stations in the control data.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Execute the instruction again after correcting the constant link scan time
in the control data.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Execute the instruction again after correcting the station number in the
network configuration setting data so it is within 1 to 120.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Execute the instruction again after correcting the station number in the
network configuration setting data to a unique value.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Execute the instruction again after correcting the number of occupied
stations in the network configuration setting data.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Execute the instruction again after correcting the station type in the
network configuration setting data.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Execute the instruction again after correcting the offset or the number of
points of link devices in the network configuration setting data.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Set the station type of the REMFR/REMTO/REMFRD/REMTOD/
REMFRIP/REMFRDIP/REMTOIP/REMTODIP instruction target station to
a remote station.
• Correct the network number and station number/IP address of the target
station of the dedicated instruction.
If the target station of the REMFR/REMTO/REMFRD/REMTOD/REMFRIP/
REMFRDIP/REMTOIP/REMTODIP instruction is disconnected, execute the
dedicated instruction again after return of the target station.
Set "Network No." under "Network No." of "Required Settings" to between 1
and 239.
Rewrite the module parameter using the engineering tool. If the same error
occurs again even after taking the above, the possible cause is a hardware
failure of the error module. Please consult your local Mitsubishi
representative.
• Correct the request command at the transient request source, and retry
the operation.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Execute the instruction again after a while.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Set the station number of the own station in the control data to a value
from 1 to 120, and retry the operation.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
Detailed
information 1
Detailed
information 2
4 TROUBLESHOOTING
223
4.5 List of Error Codes
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r cc-link ie tsn

Table of Contents