Item
Communication Period Interval (Minimum
value)
Setting Method
No.
Communication Destination
Network
Network No.
Configuration
Station No.
IP Address
Station Type
Configured Module
Model Name
Communication
Destination
PLC No.
Description
The communication cycle intervals that are calculated by the
number of slave stations and the number of points of link devices
by using the values set for standard communications and safety
communications are displayed. Use the displayed value as a
*1
guide.
The displayed value differs depending on "TSN HUB Setting" of
"Connection Device Information" under "Basic Settings" even
when the number of slave stations and link device points are the
same. For details, refer to the following.
Page 293 Communication cycle intervals
The displayed value can be used for "Communication Period
Interval Setting" in "Communication Period Setting" under "Basic
Settings" of the module parameter.
If cyclic transmission is not performed by configuring the setting
with the displayed value, set a value obtained by adding 10% as
follows.
Calculation formula: B+A0.1
A: Cyclic transmission time (minimum value)
B: Communication cycle interval (minimum value)
When the communication speed of the master station is 1Gbps
in unicast mode or multicast mode with version 1.085P or earlier
of the engineering tool (if a CC-Link IE TSN Class A slave station
with the basic cycle or normal speed cycle exists), the interval
cannot be checked. Check it with 'Communication cycle interval
(calculation value)' (SW0072).
Page 274 List of link special register (SW)
Right-click in the "Safety Communication Setting" window and
select an assignment method in "Safety Data Transfer Device
Setting".
• Start/End: Enter the start and end numbers of safety devices.
• Points/Start: Enter the points and start numbers of safety
devices.
Safety connection number for distinguishing settings for each
safety connection.
Set a network of the communication destination.
The network number of the communication destination is
displayed.
When the own station is the master station: The station number
of communication destination selected in the "Select the target
module for the Safety Communication Setting" window is
displayed.
When the own station is the master station: The IP address of
communication destination selected in the "Select the target
module for the Safety Communication Setting" window is
displayed.
When the own station is the master station: The station type of
the communication destination selected in the "Select the target
module for the Safety Communication Setting" window is
displayed.
When the own station is the master station: The module model
name of the communication destination selected in the "Select
the target module for the Safety Communication Setting" window
is displayed. (Only slave station other than the local station)
When the communication destination is a local station: Set the
CPU model name of communication destination.
When the own station is the master station: Set the CPU number
of the communication destination when the CPU module of the
communication destination is set to CPU module other than the
Safety CPU.
Setting range
• Start/End
• Points/Start
(Default: Start/End)
*2
1 to 120
Local Network
(Default: empty)
0.0.0.1 to 223.255.255.254
(Default: empty)
• R08SFCPU
• R16SFCPU
• R32SFCPU
• R120SFCPU
• R16NCCPU
• CR800-R
(Default: empty)
2 to 4
(Default: empty)
2 PARAMETER SETTINGS
2.3 Basic Settings
2
107