Chapter 6 • Hydran 201Ti Installation
2.
Connect the cable to the H201Ti's terminals L1/L, L2/N and E/G. For wiring details,
see Table D-1 on page D-1.
3.
Connect the other end of the cable to the power source.
Note: The earth/ground terminal (E/G) must be connected to the power source ground
(green wire) or directly to the transformer tank. See the special considerations regarding
grounding at the beginning of Section 6.3.8 on page 6-25.
Never perform high-voltage tests (mega-ohm measurements using a
WARNING
CAUTION
Megger* instrument) on cables connected to a H201Ti or a
Hydran 201Ci Controller. Never apply high voltages to the
components of a Hydran 201i System, as they are equipped with
surge protection devices that could be damaged by Megger* tests.

6.3.12 Installing the CPU Module

1.
Align and carefully insert the CPU module on the central post of the Hydran 201Ti
until the connector (at the back of the module) is completely inserted in the mating
connector.
2.
Fasten the module with the two 6-32 screws (see Figure 6-9 on page 6-29).
When fastening the CPU module, ensure not to bend the pins of the
WARNING
CAUTION
connector located between the CPU and I/O modules.

6.3.13 Verifying the Hydran 201Ti Operation

1.
Power up the H201Ti.
2.
Perform the procedure described in Section 6.2.2 on page 6-7.
6-28