Preparing The Valve; Installing The Brass Adaptor Onto The Valve; Figure 6-4 - Always Cover The Threads Of The Adaptor And Sensor With Teflon - GE Hydran 201 i Instruction Manual

Hide thumbs Also See for Hydran 201 i:
Table of Contents

Advertisement

Electric Canada. Reconnect the battery before installation; procedures to disconnect and
reconnect the battery are both given in Section 2.7.2 on page 2-15
6.3.3

Preparing the Valve

1.
Wipe the inside of the valve.
2.
Clean the valve's threads.
3.
Wipe up any trace of oil and dispose of the collected oil according to company
standards.
6.3.4

Installing the Brass Adaptor Onto the Valve

1.
Cover the adaptor's threads with Teflon tape (see Figure 6-4 on page 6-21).
Use only Teflon tape to seal the threads of both the adaptor and
WARNING
CAUTION
Hydran 201 sensor. Wrap at least 4 to 5 layers of tape around the
threads.
Always wrap the tape
counter to the threads
Teflon
Figure 6-4 - Always Cover the Threads of the Adaptor and Sensor With Teflon Tape
Part 17997
Teflon
Rev. 6, March 2011
Installation
6-21

Advertisement