Nozzle Up-Status Detection Sensor Amplifier Adjustment - Yamaha SIGMA-G5SII Service Information

Table of Contents

Advertisement

(2) Shutter Open/Close Speed Adjustment
Adjust the speed controller (SPICON) to set the shutter open/close time as follows.
Open: 80 +/- 5msec. (From valve signal ON to sensor OFF)
Close: 80 +/- 5msec. (From valve signal OFF to sensor ON)
Fig.C16

3.1.5.3. Nozzle Up-Status Detection Sensor Amplifier Adjustment

(1) Amplifier Cable Wiring Arrangement
a. Standard: The nozzle stocker for multi-functional nozzle is setup in the first line.
b. Standard: The nozzle stocker for multi-functional nozzle is setup in the Fouth line.
c. Standard: The nozzle stockers for multi-functional nozzle are setup in first and the
fourth lines.
(2) Sensor Amplifier Teaching
Set the nozzle up-status detection fiber amplifier using the following procedure.
Service Information
CH1:Connection
CH2:Use a snippet of the fiber cable.
CH1:Use a snippet of the fiber cable.
CH1:Connect the first line.
CH2:Connect the four line.
SI1705004E-00=SIGMA-G5SII Service Manual
93/273
For Service Engineer