2.3.2. Nozzle Change Procedure in the "Unit Adj." Window

Housing the Nozzle in the Stocker
1)
Select "Maint.", "Unit Adj." and
CHNG
"
Select the subject head, nozzle and
stocker and press the "Reset Nozzle
"button and press the [START]
button on the operation panel.
(2) Placing the Nozzle onto the Head
Select the subject head, nozzle and
stocker and press the "Set Nozzle"
button and press the [START] button
on the operation panel.
* When the nozzle is to be changed in the "Unit Adj." window, make sure to perform the
nozzle level teaching and nozzle position teaching after any nozzle change.
Example : Housing the nozzle No. 1 on the Head No. 1 to the Position No. 1 in the
H2 Stocker Section
15...........3,2,1 Position No.
[1]
Select the "Head No. 1" and
"Nozzle No. 1".
".
Stocker No. 1 in the H1 Stocker Section
H1 Nozzle 1
・ ・
4 ・
3
15
2
1
Stocker 1
Stocker 2
Stocker 3
Stocker 4
START
[4]
Press the [START] button on the operation panel.
Service Information
Position No. 1,2,3............15
[2]
Select the location where
the nozzle is to be housed
(Position No. 1 in the H1-
Stocker No. 1)
SI1705004E-00=SIGMA-G5SII Service Manual
65/273
For Service Engineer
H1 Stocker Section
Stocker 4
Stocker 3
Stocker 2
Stocker 1
[3]
Select "Reset
Nozzle".