Unit Adjustment; Linear Measure Detection Test; Cutter Operation - Yamaha SIGMA-G5SII Service Information

Table of Contents

Advertisement

2.7.1. Unit Adjustment

2.7.1.1. Linear Measure Detection Test

Select "Unit Adj." and "LINE MEAS" in this order and select "Dtct Test" tab sheet.
Select the subject head and press the "Opration" button and then press [START] button, on
the operation panel.
Confirm that there is no value outside the range for the judgment level.

2.7.1.2. Cutter Operation

Select "Unit Adj." and "Cutter" in this order and check the cutter unit operation in the
"Cutter" window.
Connect the feeder cart connecting connector to the main machine and perform the "Zero
for maintenance" operation in the window. Then select a mode in the window and press the
"Manual Opn" button and press [START] button on the operation panel.
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
75/273