(3) Remarks

2.4. Conveyor Width Adjusting Procedure

(1) The conveyor width adjusting procedure when the jig is to be setup on the conveyor for
various teaching operations, is described as follows.
(2) Select " Unit Adj. " and " Conveyor " in the " Maint. " window.
The operation procedure is described as follows, taking an example of setup of the
"placement height confirmation supporting jig" (JG-0191) (160 × 80mm).
[1] Select "Conveyor".
(Because, in the SIGMA Series the width of the "L-Conveyor" or "R-Conveyor" can
not be changed independently, it is not required to select any of these buttons. Even
when such a button is selected, the operation same as in the case of selecting
"Conveyor", is performed.)
[2] When the value in the "Tgt Wd" box is clicked, the "Ten-key" window opens.
[3] When "80" is entered in the box and the "Set" key is clicked, the target value is
changed to "80mm".
[4] As above, input "0.8" in the "Clearance" text box.
[5] Select "Desig Width" button and then press the [START] button on the operation
panel.
The conveyor width is changed to the set value.
Then, perform the following operation.
* When the user set value for the "Clearance" is changed, return to the previous value
when the operation is completed.
Service Information
The history of the nozzle placement, about from
which position of the stocker, the subject nozzle was
picked up, is described.
In this example, it shows that the nozzle is taken out
from the Position No. 1 of the H1-Stocker No. 1.
In the nozzle collective storage in the "Setup" menu,
the nozzle No. 1 is housed in this location.
SI1705004E-00=SIGMA-G5SII Service Manual
66/273
For Service Engineer