Notes on Output Terminal
The PV310 has a low load capacity, which allows you to connect the device to a PLC, etc. Do not directly
connect the PV310 to a device having a high load capacity, such as a valve, without passing it through our
Power-Photo relay.
The output circuit contains no built-in fuse. If it is necessary to prevent from burning out the output circuit in
the event of output load short circuit, mount an external fuse. However, it may not be able to protect
internal elements in the event of short circuit.
The COMMON terminal is exclusively for FLASH. Do not commonly use the terminal with other COM
terminals.