10.2.2 Starting Inspection - Repeat

If "Start" is set to "Repeat", after the PV310 is activated, the PV starts an inspection without waiting for START
signal (STA) input from the external device. After the first inspection is completed and READY signal is recovered,
READY signal turns off and the device executes an inspection without waiting for the next START signal input.
To stop the inspection, execute one of the following,
Input the START signal
Send "%SCR " (a serial command)
Press the A key of the keypad for one second
If one of the above is operated again after the inspection stopped, inspection will be repeatedly executed.
Timing Chart
T1< 1 ms
T2 = Inspection execution time or Minimum READY signal OFF time. The time varies depending on setting.
T3 = Min. 1 ms
1.
PV310 is activated after the power is supplied. READY signal turns off in 1 ms after PV was
activated and the PV starts the first inspection.
2.
After the PV310 completed capturing an image, the REND signal is turned on.
3.
The program is executed and D1 to D8 are output.
4.
After outputting D1 to D8, the READY signal is recovered (OFF to ON) and the REND signal is
turned off as well.
5.
Within 1 ms, the READY signal turns off and the second inspection is executed.
After that, inspection is repeatedly executed.
Refer to "Starting Inspection-ONCE" for the timing of result output.
When the execution mode is set to "User-defined", Block 1 is executed regardless of the input status of
IN1-2. To execute Block No. 2 or No 3, pause the inspection, specify block No. for IN1-2 and restart the
inspection.