Timing Chart
Area Display: No (When "Template Setting" is assigned to FCT2.)
1.
Assign the numbers of the target checkers to re-register to IN1-7.
(Input the data more than 1 ms before FCT2 signal input).
2.
Make sure that READY signal and input FCT1 signal.
After READY signal is turned off, the template is re-registered.
3.
Make sure that the READY signal is off and then turn the FCT2 signal off.
After re-registering the template is completed, the READY signal is turned on.
You cannot re-register the templates of the following checkers by inputting a signal from the external
device.
- Position Adjustment (Matching)
- Rotation Adjustment (Matching)
- Rotation Adjustment (Contour)
If the image cannot be re-registered or the image has no features), ERROR signal will be output.
If the external device cannot recognize that READY signal has been recovered (OFF > ON) due to short
product switch time, set Min. Ready Off time by selecting "ENVIRONMENT" > "Initial Settings" from the
menu bar.
When a live image is displayed, a new image is re-registered after capturing the image.
When a memory image is displayed, the currently displayed memory image (captured last) is
re-registered.
If you do not want to let the PV310 lose the images after power is removed, save the current settings by
selecting "SAVE" from the menu bar or by inputting the command "%MCR" from the external device.