Command format: Fixed Length
Communication direction
From external device to PV310
Response: Normal (at the end
of specifying the number of
command digits)
Response: Error 1
Response: Error 2
ERROR signal = "ON"
Error Code: E0177 is
displayed on the screen
Command / Description
%
G
?
?
n
n
??: 01 to 99 (Specify the number of the target checker in 2-digit form)
nnnn: 0001 to 0255 or 001 to 0255 (Specify edge threshold in 4-digit form)
nnnn
:0001 to 0255: Unused digits are filled with '0'.
nnnn
:0001 to 0255: Unused digits are filled with 'Blanks'.
%
G
?
?
n
n
The same command as the sending command from external device to PV310 is
transmitted.
%
U CR
Cause:
Command in the unspecified form or not provided was received.
Examples:
C
%G1,80
(any other checker number than 01 to 99 was specified)
-
R
C
%B01,80
(not provided command)
-
R
%
Z CR
Causes:
The target checker is not saved as the number of the checker specified by the
sending command.
The edge threshold specified by the sending command is not between 001 or 1
and 255.
n
n CR
n
n CR