Gray Edge- Reading Edge Threshold ([%H]) (For Gray Edge checker)
Communication Direction
From external device to PV310
Response: Normal
Response: Error 1
Response: Error 2
ERROR signal = "ON"
Error Code: E0176 is
displayed on the screen
270
Command / Description
%
H
?
? CR
?? : 01 to 99 (Specify the number of the target checker in 2-digit form)
Serial Communication - Command: "Comma separated"
%
H
?
?
,
n
?? : 01 to 99 (Checker No.: 2 digits)
nnn: 001 to 255 (Edge threshold: 1 to 3 digits)
Serial Communication - Command: "Fixed Length"
%
H
?
?
n
n
?? : 01 to 99 (Checker No.: 2 digits)
nnnn: 0001 to 0255 or 001 to 0255 (Edge threshold)
nnnn
:0001 to 0255: Unused digits are filled with '0'.
nnnn
:0001 to 0255: Unused digits are filled with 'Blanks'.
%
U CR
Cause:
Command in the unspecified form or not provided was received.
Examples:
C
-
%T1,80,255
(any other checker number than 01 to 08 was specified)
R
C
-
%B01
(not provided command)
R
%
Z CR
Causes:
The checkers saved as the specified number are different from the target
checkers of this command.
No checkers are saved as the specified numbers.
n
n CR
n
n CR