Refering To Position Adjustment Amount Using Checkers - Panasonic MICRO-IMAGECHECKER PV310 Use Manual

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

6.12.2 Refering to Position Adjustment Amount Using Checkers

Since multiple Position Adjustment checkers can be set, the amount of the position adjustment checker to which
each checker refers differs depending on the Position Adjustment number. If you choose "01", the checker refers
to the adjustment amount of Position Adjustment checker No. 1
In addition, not only checkers for inspection but also position adjustment checkers can refer to the adjustment
amount of other Position Adjustment or Rotation Adjustment checkers. Follow the same steps used for other
checkers.
Note:
When any checker refers to the adjustment amount of a Position Adjustment checker, the number of
rotation-adjustment-referenced checkers must be lower than the number of the rotation-adjustment-referenced
checker. This is because each checker is executed in ascending order and the position adjustment checker of
lager number than the checker holds only the adjustment amount data for the last inspection.
The PV310 features a function that multiple checkers referencing to the same Position Adjustment checker
can be moved at a time. Refer to page 240 for further information.