Changing Max. / Min. Values In Run Mode - Panasonic MICRO-IMAGECHECKER PV310 Use Manual

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

7.5.7 Changing Max. / Min. Values in RUN Mode

In RUN mode, you can change the Max. / Min. values of Numeric Calculation that are displayed in the Data
Monitor table.
Setting Procedure
When the Data Monitor table is displayed in RUN mode, follow the steps below.
1.
Select an item in the Data Monitor table to change the Max. and Min. values.
READY signal is turned off and the subwindow is displayed.
2.
Highlight the Max. /Min.
The cursor moves the value on the right.
3.
Change the value and press the ENTER key.
4.
Press the C key.
After the subwindow disappears, the READY signal is turned on.
The PV310 does not accept any signal including START signal (but, not including key emulation command)
from the external device while READY signal is off. Therefore, even if the START signal is input from the
external device, it does not trigger the execution of inspection.
198

Advertisement

Table of Contents
loading

Table of Contents