Siemens SINAMICS G120 Operating Instructions Manual page 376

Low voltage converters, chassis and wall/panel mounted devices with cu230p-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Technical data
10.2 Technical data, Power Modules
Table 10- 4
PM230, IP20, frame sizes A, 3 AC 380 V ... 480 V
Article No. - without filter
Article No. - with filter
LO base load power
LO base load input current
LO base load output current
HO base load power
HO base load input current
HO base load output current
Fuse according to IEC
Fuse according to UL
Power loss
Required cooling air flow
Cross section of line and motor cables
Tightening torque for line and motor cables
Weight without filter
Weight with filter
Table 10- 5
PM230, PT, frame sizes A, 3 AC 380 V ... 480 V
Article No. - without filter
Article No. - with filter
LO base load power
LO base load input current
LO base load output current
HO base load power
HO base load input current
HO base load output current
Fuse according to IEC
Fuse according to UL
Power loss
Required cooling air flow
Cross section of line and motor cables
Tightening torque for line and motor cables
Weight without filter
Weight with filter
376
6SL3210...
...1NE17-7UL1
6SL3210...
...1NE17-7AL1
3 kW
8.0 A
7.7 A
2.2 kW
6.1 A
5.9 A
3NE1 813-0
AJT10 / 3NE1 813-0
0.11 kW
4.5 l/s
1.5 ... 2.5 mm
16 ... 14 AWG
0.5 Nm / 4 lbf in
1.4 kg
1.6 kg
6SL3211...
...1NE17-7UL1
6SL3211...
...1NE17-7AL1
3 kW
8.0 A
7.7 A
2.2 kW
6.1 A
5.9 A
3NE1 813-0
AJT10 / 3NE1 813-0
0.11 kW
4.5 l/s
1.5 ... 2.5 mm
16 ... 14 AWG
0.5 Nm / 4 lbf in
1.7 kg
1.9 kg
2
2
Converter with CU230P-2 Control Units
Operating Instructions, 04/2015, FW V4.7 SP3, A5E34257946B AB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120cSinamics g120p

Table of Contents