Siemens SINAMICS G120 Operating Instructions Manual page 198

Low voltage converters, chassis and wall/panel mounted devices with cu230p-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Advanced commissioning
6.2 Inverter control
Status word 1 (ZSW1)
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
If you change over from another telegram to telegram 20, then the assignment of the previous
1)
telegram is kept.
Further information
You can find additional information about BACnet MS/TP in the "Fieldbuses" Function
Manual: Manuals for the Control Unit
(http://support.automation.siemens.com/WW/view/en/30563628/133300).
198
Meaning
1 = Ready to start
1 = Ready
1 = Operation enabled
1 = Fault active
1 = OFF2 inactive
1 = OFF3 inactive
1 = Closing lockout active
1 = Alarm active
1 = Speed deviation within the
tolerance range
1 = Master control requested
1 = Comparison speed reached or
exceeded
1 = Torque limit not reached
Reserved
0 = Alarm, motor overtemperature --
1 = Motor rotates clockwise
0 = Motor rotates counterclock-
wise
0 = Alarm, inverter thermal over-
load
Remarks
Power supply switched on; elec-
tronics initialized; pulses locked.
Motor is switched on
(ON/OFF1 = 1), no fault is active.
With the command "Enable opera-
tion" (STW1.3), the inverter
switches on the motor.
Motor follows setpoint. See control
word 1, bit 3.
The inverter has a fault.
Acknowledge fault using STW1.7.
Coast down to standstill is not
active.
Quick stop is not active.
It is only possible to switch on the
motor after an OFF1 followed by
ON.
Motor remains switched on; no
acknowledgement is necessary.
Setpoint / actual value deviation
within the tolerance range.
The automation system is request-
ed to accept the inverter control.
Speed is greater than or equal to
the corresponding maximum
speed.
Comparison value for current or
torque has been fallen below.
Internal inverter actual value > 0
Internal inverter actual value < 0
Operating Instructions, 04/2015, FW V4.7 SP3, A5E34257946B AB
Signal interconnection
in the inverter
p2080[0] = r0899.0
p2080[1] = r0899.1
p2080[2] = r0899.2
p2080[3] = r2139.3
p2080[4] = r0899.4
p2080[5] = r0899.5
p2080[6] = r0899.6
p2080[7] = r2139.7
p2080[8] = r2197.7
p2080[9] = r0899.9
p2080[10] = r2199.1
p2080[11] = r0056.13 /
r1407.7
p2080[12] = r0899.12
p2080[13] = r2135.14
p2080[14] = r2197.3
p2080[15] = r2135.15