Mitsubishi Electric MELSEC-Q Series User Manual page 64

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

• Remote register (RWw)
Because an AJ65BTB2-16T and AJ65BTB1-16DT are remote I/O stations, the remote register (RWw) is
not used. Note, however, that four points (equivalent to the points for one station) are occupied in the
master/local module because the system is in the remote net Ver.1 mode.
CPU module
W100
W103
W104
W107
Using the remote net Ver.2 mode can reduce the number of devices by assigning zero points to RWr and RWw in a remote
I/O station. (
3.
Mount the master/local module on a base unit. (
62
Master station
Buffer memory
(Remote register (RWw))
Device
1E0
Station No.1
Station No.1
1E3
1E4
Station No.2
Station No.2
1E7
Page 48, Section 3.6.4)
AJ65BTB2-16T output module
Remote I/O station
(output 16 points)
Station No.1
(480)
H
(481)
H
(482)
H
(483)
H
Device actually used by the remote I/O stations
Page 75, Section 6.1)
AJ65BTB1-16DT combined module
Remote I/O station
(input 8 points, output 8 points)
Station No.2