Communication and automatic update buffer assignment data
Parameter registration (data link startup)
Process at completion of the G(P).RLPASET instruction
Start of the control program
Refresh of RX
Refresh of RWr
Station number 1 control program
Station number 2 control program
Station number 3 control program
Refresh of RWw
Refresh of RY
Refresh of SB/SW
*2 D150 and D160 are dummy devices.
Perform abnormal end process.
Station number 1 control program
Station number 2 control program
Station number 3 control program
CHAPTER 9 DEDICATED INSTRUCTIONS
First (station number 1) local station
Send buffer: 100 word
First (station number 1) local station
Receive buffer: 100 word
First (station number 1) local station
Automatic update buffer: 0 word
Dedicated instruction
*2
(G(P).RLPASET)
Turn the parameter setting
instruction off.
Instruct to refresh at normal
completion of the
G(P).RLPASET instruction.
Instruct to start the control program
at normal completion of the
G(P).RLPASET instruction
Data in RX00 to RX5F are read to
X1000 to X105F.
Data in RWr0 to RWr3 are read to
D1000 to D1003.
Data in RWw0 to RWw3 are written
into D2000 to D2003.
Data in RY00 to RY5F are written
into Y1000 to Y105F.
Data in SB0000 to SB001F are
refreshed.
Data in SW0000 to SW001F are
refreshed.