9.4

G(P).RIRCV

The G(P).RIRCV instruction automatically performs handshaking with the intelligent device station and reads data
from the buffer memory areas of the specified intelligent device station.
The instruction is available for modules that have a handshake signal (e.g. AJ65BT-R2(N)).
[Instruction
[Execution
symbol]
condition]
G.RIRCV
GP.RIRCV
Setting
Internal device
data
(System, user)
Bit
Word
(S1)
(D1)
(S2)
(D2)
(1) Setting data
*1
Device
Start I/O number of the module (First two digits of I/O number written
Un
with three digits)
(S1)
Start number of the device in which control data is stored
(D1)
Start number of the device to which read data is stored
(S2)
Start number of the device in which an interlock signal is stored
Device that turns on for one scan upon completion of reading.
(D2)
(D2) + 1 also turns on at an abnormal end.
*1
The local device and the file register of each program cannot be used as a device for setting data.
Command
G.RIRCV
Command
GP.RIRCV
Applicable device
Link direct
device
File
J\
register
Bit
Word
Description
CHAPTER 9 DEDICATED INSTRUCTIONS
Un
(S1)
(D1)
Un
(S1)
(D1)
Intelligent
function module
Index
device
register Z
U\G
Setting range
0 to FE
Within the range of the
specified device
Within the range of the
specified device
Within the range of the
specified device
Within the range of the
specified device
(S2)
(D2)
(S2)
(D2)
Constant
Others
K, H
$
Data type
16-bit binary
H
Device name
Bit
187
9