Appendix 3.2 Link Special Registers (Sws) - Mitsubishi Electric MELSEC-Q Series User Manual

Cc-link system master/local module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Appendix 3.2
Data are stored in SW0000 to SW001F using a program, whereas data are automatically stored in SW0020 to
SW01FF.
Values in parentheses are buffer memory addresses.
When a standby master station is used, refer to the respective columns under "Availability" in the table as explained
below.
• When a standby master station is operating as a master station: "Master station" column
• When a standby master station is operating as a standby master station: "Local station" column
Number
Name
Select whether to specify multiple temporary error invalid stations.
Multiple
00: Multiple stations set in SW0004 to SW0007 specified
SW0003
temporary error
01 to 64:
(603
)
invalid station
H
specification
Specify a temporary error invalid station.
0: Temporary error invalid station not specified
SW0004
1: Temporary error invalid station specified
(604
)
H
SW0005
(605
)
Temporary error
H
invalid station
SW0006
specification
(606
)
H
SW0007
The stations need not be set by the number of occupied stations.
(607
)
H
Error invalid stations, reserved stations, station with the last station
number, and stations later than that are excepted.
Set a station number where the line test is executed.
SW0008
Line test station
0: Entire system (executed to all stations)
(608
)
setting
01 to 64: Target station number
H
Default: 0
Set monitoring time when dedicated instructions are used.
Default: 10 (seconds)
Range: 0 to 360 (second)
If a value outside the range is set, the monitoring time will be 360
SW0009
Monitoring time
seconds.
(609
)
setting
H
When SW000B is set, the time until a dedicated instruction fails is as
follows:
(Number or retries + 1) × monitoring time
Set monitoring time between a dedicated instruction executed to the
CPU module and the CPU module responding to it.
SW000A
CPU monitoring
Default: 90 (seconds)
(60A
)
time setting
Range: 0 to 3600 (second)
H
If a value outside the range is set, the monitoring time will be 3600
seconds.
Link special registers (SWs)
Description
A single station specified from 1 to 64
(The number represents the station number to be set as a
temporary error invalid station.)
b15
b14
b13
b12
SW0004
16
15
14
13
SW0005
32
31
30
29
SW0006
48
47
46
45
SW0007
64
63
62
61
1 to 64 in the table indicate station numbers.
to
b3
b2
b1
b0
to
4
3
2
1
to
20
19
18
17
to
36
35
34
33
to
52
51
50
49
APPENDICES