4.7.2
Giving a start command from the operation panel
for JOG operation
• JOG operation is performed while
The following shows the procedure to operate at 5 Hz.
Operating procedure
1.
Turning ON the power of the inverter
The operation panel is in the monitor mode.
2.
Changing the operation mode
Press
3.
Start → acceleration → constant speed
Hold
Jog acceleration/deceleration time, and "
4.
Deceleration → stop
Release
deceleration time. "
NOTE
• To change the running frequency, change the setting of Pr.15 Jog frequency (initial value: 5 Hz).
• To change the acceleration/deceleration time, change the setting of Pr.16 Jog acceleration/deceleration time (initial value:
0.5 seconds).
Parameters referred to
Pr.15 Jog frequency, Pr.16 Jog acceleration/deceleration
160
4. BASIC OPERATION
4.7 Basic operation procedure (JOG operation)
twice to choose the PUJOG operation mode. The display shows "
or
down to keep the JOG operation. The frequency increases according to the setting of Pr.16
or
. The frequency decreases according to the setting of Pr.16 Jog acceleration/
" (0.00 Hz) appears on the LCD display, and the motor stops rotating.
timepage 390
or
on the operation panel is pressed.
Operation panel
(FR-DU08)
" (5.00 Hz) appears on the LCD display.
", and [PU] indicator is ON.