Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 426

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Pr.
Name
774
Operation panel monitor
M101
selection 1
775
Operation panel monitor
M102
selection 2
776
Operation panel monitor
M103
selection 3
992
Operation panel setting dial
M104
push monitor selection
170
Watt-hour meter clear
M020
563
Energization time carrying-
M021
over times
268
Monitor decimal digits
M022
selection
891
Cumulative power monitor
M023
digit shifted times
171
Operation hour meter clear
M030
564
Operating time carrying-
M031
over times
290
Monitor negative output
M044
selection
1018
Monitor with sign selection
M045
1106
Torque monitor filter
M050
1107
Running speed monitor
M051
filter
1108
Excitation current monitor
M052
filter
 Monitor items list (Pr.52, Pr.774 to Pr.776, Pr.992)
• Use Pr.52, Pr.774 to Pr.776, or Pr.992 to select the item to monitor on the operation panel or the parameter unit.
• Refer to the following table to find the setting value for each monitoring. (The items marked with "—" cannot be selected.
The circle in the [-] column indicates that the indication of negative signed numbers is available.)
Increment
Monitor item
and unit
Output frequency
*17
0.01 Hz
*18
(speed)
*7*9*18
Output current
0.01/0.1 A
*7*18
0.1 V
Output voltage
Initial value
Setting range
1 to 3, 5 to 14,
17 to 20, 22 to
36, 38 to 46, 50
9999
to 57, 61, 62,
64, 67, 71 to 75,
87 to 98, 100,
9999
0 to 3, 5 to 14,
17 to 20, 22 to
0
36, 38 to 46, 50
(set frequency)
to 57, 61, 62,
64, 67, 71 to 75,
87 to 98, 100
0
10
9999
9999
(0 to 65535)
0
(Read-only)
0
9999
1
9999
0 to 4
9999
9999
0
9999
9999
(0 to 65535)
0
(Read-only)
0
0 to 7
0
9999
9999
0 to 5 s
9999
9999
0 to 5 s
9999
9999
0 to 5 s
9999
9999
RS-485
Pr.52,
communication
Pr.774 to
dedicated
Pr.776,
monitor
Pr.992
(hexadecimal)
1/0/100
H01
*6
2/0/100
H02
3/0/100
H03
Each of the initial items monitored on the operation panel or
parameter unit in the monitor mode (output frequency,
output current, and output voltage) can be switched to an
user-designated item.
9999: Follows the Pr.52 setting.
Select the monitor item displayed on the operation panel at
the time when the setting dial is pressed.
Set "0" to clear the watt-hour meter.
Set "10" to monitor the cumulative power in the range of 0 to
9999 kWh via communication.
Set "9999" to monitor the cumulative power in the range of
0 to 65535 kWh via communication.
The number of times that the cumulative energization time
exceeded 65535 hours is displayed (read-only).
Value is displayed in 1 increments (an integer).
Value is displayed in 0.1 increments.
No function
Set the number of digits to move the decimal point of the
cumulative energy monitored value to the left. The readout
peaks out at the upper limit of readout.
The function of moving the decimal point is not available.
The readout is reset to 0 when it exceeds the upper limit.
Set "0" to clear the operation hour meter.
The readout is always 9999. Nothing changes when "9999"
is set.
The number of times that the operating time reaches 65535
hours is displayed. Read-only.
Set the availability of negative signals output via terminal
AM, to the operation panel, and through communication.
(Refer to
page
433.)
Select the item group to enable the indication of negative
signed numbers.
The filter time constant is selectable for monitoring of the
torque. A larger setting results in slower response.
0.3 s filter
The filter time constant is selectable for monitoring of the
running speed. A larger setting results in slower response.
0.08 s filter
The filter time constant is selectable for monitoring of the
motor excitation current. A larger setting results in slower
response.
0.3 s filter
MODBUS
RTU real
*1
-
time
monitor
*21
40201
The inverter output frequency is displayed.
The inverter output current effective value is
40202
displayed.
40203
The inverter output voltage is displayed.
5.11 (M) Item and output signal for monitoring
Description
Description
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
425