Output Signal List - Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Pr.
Name
190
RUN terminal
M400
function selection
191
SU terminal function
M401
selection
192
IPF terminal function
M402
selection
193
OL terminal function
M403
selection
194
FU terminal function
M404
selection
195
ABC1 terminal
M405
function selection
196
ABC2 terminal
M406
function selection
313
DO0 output
*3*4
selection
M410
314
DO1 output
*3*4
selection
M411
315
DO2 output
*3*4
selection
M412
316
DO3 output
*3
selection
M413
317
DO4 output
*3
selection
M414
318
DO5 output
*3
selection
M415
319
DO6 output
*3
selection
M416
320
RA1 output selection
*3
M420
321
RA2 output selection
*3
M421
322
RA3 output selection
*3
M422
Pr.
Name
289
Inverter output terminal
M431
filter
*1
The initial value is for standard models and IP55 compatible models.
*2
The initial value is for separated converter types.
*3
The setting is available when the PLC function is enabled or when a compatible plug-in option is installed.
*4
The setting is available for the FR-A800-GF.
 Output signal list
• A function listed below can be set to each output terminal.
• Refer to the following table and set the parameters. (0 to 99: Positive logic, 100 to 199: Negative logic)
Setting
Signal
Positive
Negative
name
logic
logic
0
100
RUN
1
101
SU
Initial
value
0
RUN (Inverter running)
1
SU (Up to frequency)
For open
IPF (Instantaneous power
*1
2
collector
failure/undervoltage)
output
*2
No function
9999
terminal
3
OL (Overload warning)
FU (Output frequency
4
detection)
99
ALM (Fault)
For relay
output
terminal
9999
No function
9999
No function
9999
No function
9999
No function
9999
No function
For
9999
No function
terminal
on the
9999
No function
option
9999
No function
9999
No function
9999
No function
9999
No function
Initial
Setting range
value
5 to 50 ms
9999
9999
Function
Inverter running
*1
Up to frequency
Signal name
0 to 8, 10 to 20, 22, 25 to 28, 30 to 36, 38 to 57,
60, 61, 63, 64, 67, 68, 70, 79, 80, 84, 85, 90 to
99, 100 to 108, 110 to 116, 120, 122, 125 to
128, 130 to 136, 138 to 157, 160, 161, 163,
164, 167, 168, 170, 179, 180, 184, 185, 190 to
199, 200 to 208, 211 to 213, 300 to 308, 311 to
313, 9999
0 to 8, 10 to 20, 22, 25 to 28, 30 to 36, 38 to 57,
60, 61, 63, 64, 67, 68, 70, 79, 80, 84, 85, 90, 91,
94 to 99, 100 to 108, 110 to 116, 120, 122, 125
to 128, 130 to 136, 138 to 157, 160, 161, 163,
164, 167, 168, 170, 179, 180, 184, 185, 190,
191, 194 to 199, 200 to 208, 211 to 213, 300 to
308, 311 to 313, 9999
0 to 8, 10 to 20, 22, 25 to 28, 30 to 36, 38 to 57,
60, 61, 63, 64, 68, 70, 79, 80, 84 to 99, 100 to
108, 110 to 116, 120, 122, 125 to 128, 130 to
136, 138 to 157, 160, 161, 163, 164, 168, 170,
179, 180, 184 to 199, 200 to 208, 211 to 213,
300 to 308, 311 to 313, 9999
0 to 8, 10 to 20, 22, 25 to 28, 30 to 36, 38 to 57,
60, 61, 63, 64, 68, 70, 79, 80, 84 to 91, 94 to 99,
200 to 208, 211 to 213
Set the time delay for the output terminal response.
No filtering of the output terminal.
Operation
Outputted during operation when the
inverter output frequency reaches Pr.13
Starting frequency or higher.
Outputted when the output frequency
reaches the set frequency.
5.11 (M) Item and output signal for monitoring
Setting range
Description
Related
parameter
Pr.41
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
Refer
to
page
456
461
451