Stop-On-Contact Control - Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Confirming the starting times can be used to determine the timing of the maintenance, or can be used as a reference for system
inspection or parts replacement.
Pr.
Name
1410
Starting times lower 4
A170
digits
1411
Starting times upper 4
A171
digits
• Every start signal input (the RUN signal ON) while the inverter output is stopped is counted as the inverter starting time.
(Starting during pre-excitation is also counted.)
STF
LX
RUN
Output
frequency
Start count
indication
• The lower four digits of the number of starting times is displayed in Pr.1410 Starting times lower 4 digits, and the upper
four digits of the number of starting times is displayed in Pr.1411 Starting times upper 4 digits.
• The maximum count is "99999999". When "99999999" is exceeded on the monitor, the monitor value is reset to 0.
Display data
Pr.1410 (Lower digits monitor)
10000
Pr.1411 (Upper digits monitor)
Pr.1410 (Lower digits monitor)
100
Pr.1411 (Upper digits monitor)
NOTE
• Any value can be set in Pr.1410 or Pr.1411. Set "0" to clear the number on the monitor.
• Starting during offline auto tuning is not counted.
• Under position control, the count increases when the LX signal turns ON.
• The counting is enabled even if the RUN signal is not assigned to an output terminal.
• (For RUN signal, refer to
• Starting during the test operation (Pr.800 = "9") is not counted.

5.14.5 Stop-on-contact control

Magnetic flux Sensorless
Magnetic flux
Magnetic flux
Sensorless
Sensorless
To ensure accurate positioning at the upper limit, etc. of a lift, stop-on-contact control causes the mechanical brake to close
while the motor creates a holding torque to keep the load in contact with a mechanical stopper, etc.
This function suppresses vibration that is likely to occur when the load is stopped upon contact in lift applications, thereby
ensuring reliable and highly accurate positioning stop.
<Without stop-on-contact control>
Vibration
546
5. PARAMETERS
5.14 (A) Application parameters
Initial value Setting range
0
0
ON
ON
ON
2
1
Monitor display
page
450.)
<With stop-on-contact control>
Complete stop
Lift
Displays the lower four digits of the number of the inverter starting
0 to 9999
times.
Displays the upper four digits of the number of the inverter starting
0 to 9999
times.
ON
ON
ON
Lift
Description
ON
ON
ON
ON
4
3
Time