Simple Positioning Function By Parameters - Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

5.5.4

Simple positioning function by parameters

Vector
Vector
Vector
PM
PM
PM
Set positioning parameters such as the number of pulses (position) and acceleration/deceleration time in advance to create a
point table (point table method). Positioning operation is performed by selecting the point table.
Pr.
Name
419
Position command
B000
source selection
Digital position control
464
sudden stop
B020
deceleration time
465
First target position
B021
lower 4 digits
466
First target position
B022
upper 4 digits
467
Second target position
B023
lower 4 digits
468
Second target position
B024
upper 4 digits
469
Third target position
B025
lower 4 digits
470
Third target position
B026
upper 4 digits
471
Fourth target position
B027
lower 4 digits
472
Fourth target position
B028
upper 4 digits
473
Fifth target position
B029
lower 4 digits
474
Fifth target position
B030
upper 4 digits
475
Sixth target position
B031
lower 4 digits
476
Sixth target position
B032
upper 4 digits
477
Seventh target position
B033
lower 4 digits
478
Seventh target position
B034
upper 4 digits
479
Eighth target position
B035
lower 4 digits
480
Eighth target position
B036
upper 4 digits
288
5. PARAMETERS
5.5 Position control under vector control and PM sensorless vector control
Initial value
Setting range
0
1
2
10
0
100
110
1110
0 s
0 to 360 s
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
0
0 to 9999
Description
Simple position control by point table (position command
given by setting parameters)
Position command given by the pulse train input to the FR-
*1
A8AL
Simple pulse train position command given by the pulse
train input to the inverter
Simple position control by point table (position command
given by setting parameters)
The home position data is retained at servo-OFF.
Simple position control by point table (position command
given by setting parameters)
The monitor value of the current position 2 is cleared when
the home position return is completed.
Simple position control by point table (position command
given by setting parameters)
The home position data is retained at servo-OFF.
The monitor value of the current position 2 is cleared when
the home position return is completed.
Simple position control by point table (position command
given by setting parameters)
The absolute position control with the FR-A8APS is valid.
Set the time period until the inverter stops when the forward
rotation (reverse rotation) command is turned OFF with the
position feed forward function.
Set the target position of the point table 1.
Set the target position of the point table 2.
Set the target position of the point table 3.
Set the target position of the point table 4.
Set the target position of the point table 5.
Set the target position of the point table 6.
Set the target position of the point table 7.
Set the target position of the point table 8.
*2