Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 370

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

NOTE
• The stall prevention operation level is automatically lowered according to the cumulative value of the electronic thermal O/L
relay so as to prevent an inverter overload trip (E.THT, E.THM) from occurring.
 Lift operation adjustment (Pr.61, Pr.64)
• The application range can be expanded by setting the parameters for adjustment of Pr.61 and Pr.64.
Pr.
Name
61
Reference current
Starting frequency for
64
elevator mode
*1
The setting range of FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower
*2
The setting range of FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher
NOTE
• Even if the lift operation has been selected, inputting the JOG signal (JOG operation), RT signal (Second function selection)
or X9 signal (Third function selection) during an inverter stop will disable the automatic acceleration/deceleration and give
priority to JOG operation, second function selection or third function selection. Note that during operation, an input of JOG and
RT signal does not have any influence even when the automatic acceleration/deceleration is enabled.
• Even if Pr.61 and Pr.64 are set, changing Pr.292 automatically resets to the initial setting (9999). Set Pr.61 and Pr.64 after
setting Pr.292.
Parameters referred to
Pr.0 Torque
boostpage 672
Pr.13 Starting
frequencypage 363
Pr.14 Load pattern
selectionpage 674
Pr.19 Base frequency
voltagepage 673
Pr.22 Stall prevention operation
levelpage 409
Pr.570 Multiple rating
settingpage 326
Setting range
Set the rated motor current value such as when the motor capacity and
*1
0 to 500 A
inverter capacity differ.
*2
0 to 3600 A
Set the reference current (A) of the stall prevention operation level.
9999 (initial value)
The rated inverter output current value is the reference.
0 to 10 Hz
Set the starting frequency for the lift operation.
9999 (initial value)
Starting frequency is 2 Hz.
5.8 (F) Setting of acceleration/deceleration time and acceleration/deceleration pattern
Description
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
369

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all