Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 195

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Pr.
Pr.
group
1480
H520
1481
H521
1482
H522
1483
H523
1484
H524
1485
H525
1486
H526
1487
H527
1488
H531
1489
H532
1490
H533
1491
H534
1492
H535
1499
E415
Pr.CLR
ALL.CL
Err.CL
Pr.CPY
Pr.CHG
IPM
AUTO
Pr.MD
*1
Differs according to the capacity.
6%: FR-A820-00077(0.75K) or lower, FR-A840-00038(0.75K) or lower
4%: FR-A820-00105(1.5K) to FR-A820-00250(3.7K), FR-A840-00052(1.5K) to FR-A840-00126(3.7K)
3%: FR-A820-00340(5.5K), FR-A820-00490(7.5K), FR-A840-00170(5.5K), FR-A840-00250(7.5K)
2%: FR-A820-00630(11K) to FR-A820-03160(55K), FR-A840-00310(11K) to FR-A840-01800(55K)
1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K) or higher
*2
The setting range or initial value for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
*3
The setting range or initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
*4
The initial value for the FR-A820-00490(7.5K) or lower and FR-A840-00250(7.5K) or lower.
*5
Initial value for the FR-A820-00630(11K) or higher and FR-A840-00310(11K) and higher.
*6
Differs according to the capacity.
4%: FR-A820-00490(7.5K) or lower, FR-A840-00250(7.5K) or lower
2%: FR-A820-00630(11K) to FR-A820-03160(55K), FR-A840-00310(11K) to FR-A840-01800(55K)
1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K) or higher
*7
The value for the 200 V class.
*8
The value for the 400 V class.
*9
The setting is available only when a plug-in option that supports Vector control is installed. For the corresponding parameters of each option, refer
to the detail page.
*10 The parameter number in parentheses is that used (displayed) on the LCD operation panel and the parameter unit.
*11 The setting range or initial value for the standard model.
*12 The setting range or initial value for the separated converter type.
*13 The setting range or initial value for the IP55 compatible model.
*14 The setting is available only for standard models.
*15 The setting is available only for standard models and IP55 compatible models.
*16 The setting is available when the PLC function is enabled.
*17 The setting is available only for the FR-A800-GF or when a compatible plug-in option is installed.
194
5. PARAMETERS
5.1 Parameter list
Name
Load characteristics
measurement mode
Load characteristics load
reference 1
Load characteristics load
reference 2
Load characteristics load
reference 3
Load characteristics load
reference 4
Load characteristics load
reference 5
Load characteristics
maximum frequency
Load characteristics
minimum frequency
Upper limit warning
detection width
Lower limit warning
detection width
Upper limit fault detection
width
Lower limit fault detection
width
Load status detection
signal delay time / load
reference measurement
waiting time
Parameter for manufacturer setting. Do not set.
Parameter clear
All parameter clear
Fault history clear
Parameter copy
Initial value change list
IPM initialization
Automatic parameter
setting
Group parameter setting
Minimum
Setting range
setting
increments
0, 1 (2 to 5, 81 to 85)
1
0 to 400%, 8888, 9999
0.1%
0 to 400%, 8888, 9999
0.1%
0 to 400%, 8888, 9999
0.1%
0 to 400%, 8888, 9999
0.1%
0 to 400%, 8888, 9999
0.1%
0 to 590 Hz
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 400%, 9999
0.1%
0 to 400%, 9999
0.1%
0 to 400%, 9999
0.1%
0 to 400%, 9999
0.1%
0 to 60 s
0.1 s
(0), 1
1
(0), 1
1
(0), 1
1
(0), 1 to 3
1
1
0, 3003
1
(0), 1, 2
1
Initial value
Refer to
Customer
page
setting
FM
CA
0
417
9999
417
9999
417
9999
417
9999
417
9999
417
60 Hz
50 Hz
417
6 Hz
417
20%
417
20%
417
9999
417
9999
417
1 s
417
0
707
0
707
0
740
0
708
0
715
0
224
333
0
195

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents