Configure SNMP V3

The example is shown as CLI commands and as a Web interface procedure.

CLI: Configuring SNMP V3

This example shows how to configure SNMP v3 on the NETGEAR switches.
(Netgear Switch) #config
(Netgear Switch) (Config)#users passwd admin
Enter old password:
Enter new password:12345678
Confirm new password:12345678
Password Changed!
change the password to "12345678"
(Netgear Switch) (Config)#users snmpv3 authentication admin md5
Set the authentication mode to md5
(Netgear Switch) (Config)#users snmpv3 encryption admin des 12345678
Set the encryption mode to des and the key is "12345678"
SNMP
NETGEAR 7000 Series Managed Switch Administration Guide Version 7.3