Enable Snmp Trap; Cli: Enabling Snmp Trap; Web Interface: Enabling Snmp Trap - NETGEAR FSM726E-100NAS Administration Manual

7000 series managed switch administration guide for software version 7.3
Table of Contents

Advertisement

NETGEAR 7000 Series Managed Switch Administration Guide Version 7.3
3.
In the Client Address field, enter 0.0.0.0.
4.
In the Client IP Mask field, enter 0.0.0.0.
5.
Select the Read/Write from the Access Mode pull-down menu.
6.
Select the Enable from the Status pull-down menu.
7.
Click the Add.

Enable SNMP Trap

The example is shown as CLI commands and as a Web interface procedure.

CLI: Enabling SNMP Trap

This example shows how to send SNMP trap to the SNMP server.
(Netgear switch) #config
(Netgear switch) (Config)# snmptrap public 10.100.5.17
(Netgear switch) (Config)#snmp-server traps linkmode
when link status changes.

Web Interface: Enabling SNMP Trap

To use the Web interface to add a new community, proceed as follows:
1.
Enable send SNMP trap to the server 10.100.5.17.
a.
From the main menu, select System > SNMP>SNMP V1/V2>Trap Configuration. A screen
similar to the following displays.
Figure 21-2
b. In the Community Name field, enter public.
c.
Select SNMPv1 from the Version pull-down menu.
21-2
Enable send trap to SNMP server 10.100.5.17
Enable send link status to the SNMP server