Configuring Regional Parameters and Supplementary Services
Scripting for Cadences, Call Progress Tones, and Ring Tones
Scripting for Cadences, Call Progress Tones, and Ring Tones
Cisco Small Business SPA300 Series, SPA500 Series, and WIP310 IP Phone Administration Guide
Cisco SPA IP phones have configurable call progress tones. Parameters for each
type of tone can include a number of components, defining frequency, amplitude
and cadence.
Cadence Script
A CadScript is a mini-script that specifies the cadence parameters of a signal up
to 127 characters in length. Syntax:
S
[;S
]
1
2
where:
Si=Di(oni,1/offi,1[,oni,2/offi,2[,oni,3/offi,3[,oni,4/
offi,4[,oni,5/offi,5[,oni,6/offi,6]]]]]) and is known as a
section
oni,j and offi,j are the on/off durations in seconds of a
subscript ranges are: i = 1 or 2, j = 1 to 6.
D
is the total duration of the section in seconds. All durations can have up to
i
three decimal places to provide 1 ms resolution. The wildcard character "*"
indicates infinite duration.
The segments within a section are played in order and repeated until the total
duration is played.
Example: Normal Ring
60(2/4)
where:
•
Number of Cadence Sections = 1
•
Cadence Section 1: Section Length = 60 s
•
Number of Segments = 1
•
Segment 1: On=2s, Off=4s
•
Total Ring Length = 60s
7
segment.
The
173